Your Email required. Your Enquiry. USB cable and power supply are also included. AC AcoustiCal Calibrator — is a Class 1 device with two frequency levels and one sound pressure level. It generates two settings with either Hz or Hz at a sound pressure level of dB. Personal noise meter Suitable for use in hazardous areas Mounts on shoulder. Description Downloads Additional information Ordering Information The TSI Quest Edge 5 is an intrinsically safe, small, lightweight, data-logging noise dosimeter that provides real-time personal noise exposure readings.
Please follow the steps below prior to updating your Edge s. Note: this feature enables you to update all of your docked Edges when powered on and not in run mode. Below explains how to save configuration settings in DMS and how to send to the instrument. Note: if you wish to only send the setup, please skip to step 3.
Please refer to this section as you setup your instrument. Overview of running a study The list below is a brief overview of the steps for running a study. Page Positioning The Edge On Your Shirt Depending on what accessories you ordered with the Edge, you may have either clips on the top and bottom of the dosimeter or some other type of mounting device.
Page Checking Battery Power Overview of running a study Checking battery power Checking battery power Typically, the life of the battery is approximately 40 hours nominal without LED activated see Appendix A for specific specifications.
It is recommended to perform a daily download of the measured data while simultaneously charging the battery for maximum efficiency. Page Calibrating Overview of running a study Calibrating Calibrating It is recommended to calibrate your dosimeter before you run your study ies and after your study ies to ensure highly accurate measurement results. The steps below address how to calibrate for either a pre or post calibration.
The steps below outline how to reset your dosimeter. Turn the meter on by pressing the button. Ensure the meter is Off. When the splash screen appears, press and hold the buttons. Page Running Studies Running studies Starting a run Running studies With a couple pushes on the keypad buttons, you will be running and viewing your study ies. While running, press and hold the button.
Turn the dosimeter on and press the button to begin logging your study. To enable the lock, press button three consecutive times within one second intervals. The first section explains how to retrieve your studies from the dosimeter, and the subsequent sections will then walk you through viewing, organizing, and customizing your studies.
Select Noise Dosimetry see 1 , Edge see 2 , and Edge 5 see 3. Select the docked Edge s to download see 4. Click button. Page Viewing Data And Data Finder Page Viewing measurements on the display Viewing data and data finder page Viewing data and data finder page When you download the data via the the download feature, the data is stored and viewable via the data finder page with advanced charting, tables, and reporting capability.
Hard Hat Attachment kit A. Epaulette mount B. It is recommended to charge the battery frequently for maximum efficiency. Type Lithium Polymer Flat cell Memory capacity Post-calibration When performed, valid for the previous study. Storage Calibrations for a study are stored in the related study file. Calibrator requirement Calibrations should be performed at dB at 1kHz. Page 59 Appendix A Edge Block Diagram continued Page 3M Service 3M Service Contacting 3M Should your 3M equipment need to be returned for repair or for recalibration, please contact the service department at the following number or access the online form via the website.
If you can make measurements both with and without the contribution of a noise source of interest, you can mathematically subtract the background noise from the combined measurement, yielding the level of the noise source of interest alone.
It is the result of subtracting an A-weighted L from a simultaneously collected C-weighted L and is sometimes used as the NRR noise reduction rating factor to determine if hearing protection devices are adequate for usage in the field.
Also, referred to as Doubling Rate. Using the decibel scale, every time the sound energy doubles, the measured level increases by 3dB. Lockout Ability Prevent users from inadvertently terminating a study. Detection Management Software Offers a variety of functionality allowing the ability to intuitively interpret measurements and generate reports for export and sharing of results. The third dosimeter is enabled through Detection Management Software.
Related Accessories 5. Single Bay Edge Dock. Related Products 1.